Clinical Diagnostics • Hemoglobin A1c Testing

Keeping HPLC Simple

D-10 Hemoglobin Testing System

The D-10 is a compact, easy-to-use system that utilizes gold standard HPLC technology to deliver accurate HbA1c results without common hemoglobin variant interference.*

Start the conversation ▸

Experience the Proven Power of D-10!

Make a Difference with Ion-Exchange HPLC Technology

Gold Standard HPLC results, from the D-10 System, aids physicians in confidently diagnosing, identifies those at risk of developing the disease, or monitors the progress of those living with diabetes.

Download Brochure ⤓

Watch the video to learn how to get more done with the D-10 System's efficient workflow.

Cost Efficient

Some methods require hours of maintenance, extra wash steps, and additional quality control (QC) runs.

The D-10 System reduces technician time and costs with minimal maintenance and efficient QC. Complete multiple tests in fewer steps for optimized workflow and deliver timely, effective care.

Easy to Use

Some methods require assay parameters to be entered manually resulting in transcription errors.

The D-10 System saves time and eliminates transcription errors by enabling you to upload test parameters and lot information via media devices. No manual entry is required. Simplify technician work tasks with a touchscreen user interface and onboard computer.

Powerful Performance*

Non-separation methods may provide inaccurate results when a patient has a hemoglobin variant.

The D-10 System provides accurate HbA1c results in the presence of the most common heterozygous hemoglobin variants: HbAS, HbAC, HbAD, HbAE and elevated HbF. See the difference with numerical results and chromatograms so you can see the full patient profile.

For Use In Diagnosing Diabetes

D-10 Hemoglobin A1c Program

Be confident in reporting high quality, clinically-relevant HbA1c results to aid physicians in diagnosing those who have diabetes, identifying people at risk of developing the disease, or monitoring the progress of those living with diabetes.

Powerful Performance

HbA1c is reportable with no interference in the presence of:

  • The most common heterozygous hemoglobin variants: HbAS, HbAC, HbAD, and HbAE*
  • HbF ≤ 10%
  • Carbamylated hemoglobin (CHb) ≤ 6%
  • Labile A1c (LA1c) ≤ 3.5%
  • Acetylated hemoglobins
  • Lipemia ≤ 6,000mg/dL (60g/L)

Confidence in Your Results

NGSP certified, IFCC anchored and CE-marked

Download Brochure ⤓

D-10 Rack Loader

As your sample volume grows the D-10 grows with you

  • Expand capacity by adding a D-10 Rack Loader
  • Save time and money on expensive crossover studies and training

Streamlines Workflow

  • Offer five times greater capacity than the stand-alone D-10 System
  • Provide convenient sample loading for walk-away capability
  • Bring enhanced flexibility with STAT sample processing

Why Choose Bio-Rad's D-10 System?

"The D-10 is 'rock solid' and makes economic sense."

Matt Wheeler, Administrator

Bossier Family Medicine

"The D-10 rapidly changed the way we test."             

Jamie Justice, Quality Manager

Bossier Family Medicine

"The D-10 helps HCPs manage patients with military precision."

Dr. William Maranto, Family Practice

Bossier Family Medicine

Learn how the D-10 System provides a full patient picture to aid in diagnosing prediabetes and diabetes.

Contact a Bio-Rad representative today.

Thank you. A specialist will contact you shortly.

Hemoglobin Testing Solutions

Quality Control

Bio-Rad quality control solutions feature QC products, data management tools and services covering hundreds of analytes and thousands of methods.

Learn More ▸

BRiCare Support and Monitoring

Bio-Rad's instrument monitoring application for remote service and support. BRiCare is available for all of Bio-Rad's diagnostic instruments for continuous monitoring and remote sessions with an instrument's computer.

Download Brochure ⤓

*Interferences from common hemoglobin variants: HbAS, HbAC, HbAD, and HbAE were tested. Based on net performance criteria the results were acceptable.