The BioPlex 2200 Syphilis Total & RPR Assay helps laboratories redefine their syphilis testing workflow.
The assay combines two orthogonal tests for syphilis into one assay to simultaneously detect and differentiate both treponemal (Syphilis Total) and non-treponemal (RPR) antibodies in a single tube.
Reportable results include:
- Syphilis Total (IgG/IgM)
- RPR (Rapid Plasma Reagin)
RPR results include qualitative and/or quantitative titer determination (1:2–1:2,048*).
* Some dilutions may require a one-step offline dilution.
Simplify your syphilis testing with the BioPlex 2200 Syphilis Total & RPR Assay
Contact a Bio-Rad representative today.
Thank you for your interest!
Improve Laboratory Efficiency
Traditionally, non-treponemal RPR testing requires manual processing and dedicated technician time to prepare, process, and report sample results. The automated BioPlex RPR assay simplifies RPR testing. After loading samples on the BioPlex 2200 System, technicians can focus their time on other tasks while the samples process and results are released automatically to the LIS. For reactive results, titers can be ordered onboard the instrument.
96% Reduction in Hands-on Time
In a time and motion study of 100 samples, the BioPlex 2200 required approximately 5 minutes of hands-on time while the manual RPR workflow demanded almost 2 hours of dedicated time. The BioPlex 2200 Syphilis Total & RPR Assay improves laboratory efficiency and reduces hands-on time for syphilis testing.
Flexibility of the BioPlex Workflow
Standard syphilis testing follows either the traditional or reverse algorithm which requires running an initial test and following up with a separate method to confirm positive results. By using multiplex technology, the BioPlex 2200 Syphilis Total & RPR Assay combines the screening and confirmation tests for syphilis in one fully automated immunoassay test that reports both treponemal and/or non-treponemal results.
BioPlex 2200 Syphilis Total & RPR Workflow
*Treponemal testing to reconfirm may be required.
Standard Workflow
Assay Performance
The BioPlex 2200 Syphilis Total & RPR Assay provides high sensitivity and specificity for both treponemal and non-treponemal antibodies in a single one-step assay. The performance of the kit was compared against commercially available methods for both Syphilis Total and RPR and demonstrated excellent agreement for both prospective and retrospective samples. For medically diagnosed syphilis cases, the performance of the assay was compared against clinical diagnosis; these results were equivalent to the performance of other commercially available methods. The assay also demonstrates excellent total precision for both Syphilis Total (4.8% CV) and RPR (9.3% CV) in samples near the cutoff.
The BioPlex 2200 Solution for Syphilis Testing
Screen and confirm syphilis in one step
Fully automated treponemal and RPR, including titer
Productivity
Reduced hands on time and higher total throughput with up to 200 results per hour
Performance
Excellent sensitivity and specificity including differentiation of current and/or past infection
Consolidation
Streamlined syphilis testing algorithm. Detect, diagnose, monitor
Accuracy
Excellent precision, objective RPR reporting
Want to learn more?
Contact a Bio-Rad representative today to discover how the BioPlex 2200 Syphilis Total & RPR Assay can simplify your syphilis testing.